Product Details
The F-950 Three Gas Analyzer measures levels of Ethylene, CO2 and O2 to maintain optimal produce quality at every phase of the supply chain. The F-950’s versatile design allows it to be be scaled to many environments, from cold storage to transportation container.
Features
- Measures C2H4, CO2 and O2
- Displays results in under 30 seconds
- Past records stored on the device
- Handheld and lightweight
- Internal data logging and storage (4GB SD card)
- Battery lasts for 8+ hours
- Display easily viewed in dimly lit environments
- PolarCept!TM water filter for removing non-ethylene hydrocarbons
- The F-950 supports English, Spanish, and Portuguese on the instrument display
Specification
Sampling Flow Rate |
70mL/min |
Total Sampling Time |
80 seconds |
Data Saving |
Automated, 1 second intervals |
Display |
Sunlight visible transflective LCD |
Operating Environment |
0° C – 50° C (0-90 % humidity non-condensing) |
Operating Atmospheric Pressure |
500-1200mbar |
Dimensions |
18 cm x 13.5 cm x 5.5 cm |
Weight |
0.95 kg |
Enclosure |
Powder coated aluminum |
Battery Life |
8.5 hours |
Power Source |
Removable rechargeable lithium-ion battery |
PC Interface |
USB and WI-FI SD card + Bluetooth |
Data Recorded with Each Measurement |
Ethylene, CO2 and O2 concentrations, date, time, RH, GPS location |
Trigger Mode Measurements
|
C2H4 |
CO2 |
O2 |
Sensor Type |
Electrochemical |
Infrared Sensor, Pyroelectric detector |
Electrochemical |
Range |
0-200ppm |
0-100% |
0-100% |
Resolution |
0.1ppm |
0.01% |
0.10% |
Lower Detection Limit |
0.15ppm |
0.50% |
0.30% |
Sampling Volume |
35 ml |
12 ml |
12 ml |
Response Time |
35 seconds |
12 seconds |
12 seconds |
Accuracy (absolute) |
0.15 ppm |
0.50% |
0.30% |
Accuracy (relative) |
5% |
3% |
2% |
Offset Calibration |
Weekly |
Weekly |
Weekly |
Span Calibration |
3 months |
12 months |
6 months |
Sensor Replaceable (by user) |
yes |
no |
yes |
Lifetime |
1 year |
5 years |
2 years |
Continuous Mode Measurements
|
C2H4 |
CO2 |
O2 |
Sensor Type |
Electrochemical |
Infrared Sensor, Pyroelectric detector |
Electrochemical |
Range |
0-200ppm |
0-100% |
0-100% |
Resolution |
0.1ppm |
0.01% |
0.10% |
Lower Detection Limit |
0.2ppm |
0.01% |
0.10% |
Response Time |
80 seconds |
6 seconds |
12 seconds |
Accuracy (absolute) |
0.2 ppm |
0.01% |
0.10% |
Accuracy (relative) |
5% |
3% |
2% |
Offset Calibration |
Weekly |
Weekly |
Weekly |
Span Calibration |
3 months |
12 months |
6 months |
Sensor Replaceable (by user) |
yes |
no |
yes |
Lifetime |
1 year |
5 years |
2 year |
Visit www.felixinstruments.com to learn more about the F-950.