Product Details
The F-920 Check It! Gas Analyzer is a handheld device that measures headspace gas rapidly and reliably. Perfect for use in Modified Atmosphere Packaging (MAP) applications, quality control managers can easily take measurements with the F-920 straight out of the box, with little to no training. The lightweight, handheld package enables the user to take measurements virtually anywhere in the supply chain from the packing house to the retail shelf. The built-in data logger stores thousands of data points and conveniently communicates data through USB or Bluetooth onto a PC or tablet for later analysis.
Features
- Measures CO2 and O2 from 0-100%
- Displays results in under 6 seconds
- Previous records available for review on device
- Handheld and lightweight
- Battery lasts for 8+ hours
- Display easily viewed in dimly lit environment
- Functional across broad temperature and humidity range
- Bluetooth enabled for rapid data transfer
- Wi-Fi capabilities
Specification
Specifications
Sampling Flow Rate |
70mL/min |
Total Sampling Time |
10 seconds |
Data Saving |
Automated, 1 second intervals |
Display |
Backlit visible transflective LCD |
Operating Environment |
0º C - 50º C (0-99 % humidity non-condensing) |
Operating Atmospheric Pressure |
500-1200mbar |
Dimensions |
18 cm x 13.5 cm x 5.5 cm |
Weight |
0.95 kg |
Enclosure |
Powder coated aluminum |
Battery Life |
|
Battery Life |
Removable rechargeable lithium-ion battery |
Operating Atmospheric Pressure |
USB and WI-FI SD card + Bluetooth |
Data recorded with Each Measurement |
CO2 and O2 concentrations, date, time, RH, GPS location |
Trigger Mode Measurements
|
CO2 |
O2 |
Sensor Type |
Infrared Sensor, Pyroelectric Detector |
Electrochemical |
Range |
0 - 100% |
0 - 100% |
Resolution |
0.01% |
0.10% |
Lower Detection Limit |
0.50% |
0.30% |
Sampling Volume |
10ml |
10ml |
Response Time |
10 seconds |
10 seconds |
Accuracy (absolute) |
0.50% |
0.30% |
Accuracy (relative) |
3% |
2% |
Offset Calibration |
Weekly |
Weekly |
Span Calibration |
12 months |
6 months |
Sensor Replaceable (by user) |
no |
yes |
Lifetime |
>5 years |
2 years |
Continuous Mode Measurements
|
CO2 |
O2 |
Sensor Type |
Infrared Sensor, Pyroelectric Detector |
Electrochemical |
Range |
0 - 100% |
0 - 100% |
Resolution |
0.01% |
0.10% |
Lower Detection Limit |
0.01% |
0.10% |
Response Time |
10 seconds |
5 seconds |
Accuracy (absolute) |
0.01% |
0.10% |
Accuracy (relative) |
3% |
2% |
Offset Calibration |
Weekly |
Weekly |
Span Calibration |
12 months |
6 months |
Sensor Replaceable (by user) |
no |
yes |
Lifetime |
5 years |
2 years |
Visit www.felixinstruments.com to know more about the F-920 Check It! Gas Analyzer.