SKU:

Model PM1703MO1-1BT (PRD) Personal Radiation Detector and Dosimeter

Loading...

Description

The Model PM1703M-1BT (with Bluetooth connection with smartphones),  is the world’s smallest dual-detector design that meets ANSI standards 42.32 and 42.33 Type I for both dosimeters and personal radiation detectors (PRD). Rugged, water resistant, and reliable, the detector and electronics have been developed to meet IEC 61526 standards for radiation protection survey instruments, IP65 standard for a weather-resistant enclosure, and ANSI N42.42 for accurate collection and storage of critical information.

As an interdiction device, this sensitive scintillator will detect small traces of radiation in pedestrians, parcels, cargo, or vehicles. Vehicle mounted devices will detect radiation from an adjacent vehicle or as pedestrians are passing. The alarm modes give end users the option of loud audible and visual alarms, silent vibration alarms, or both. As a dosimeter, the Model PM1703M-1BT gives the responder an accurate accumulated dose history, with alternate alarm settings and thresholds. This allows the first responder to gauge issues like reaching a present maximum total dose or number of minutes to continue working during a radioactive event.

Quick Specs
Applications
  • Detector Type: Csl (TI) Scintillator, Geiger-Muller Tube
  • Detection type: Gamma
  • Weight: 200 g with battery
  • Size: 50.8 x 25 x 76.2 mm
  • Homeland Security
  • Emergency Responder
  • Safeguard and Nuclear Security
  • Radiological Area Mapping
  • Geological Radiation Survey

 

Features

  • Functions in wide range of applications
  • Bluetooth connectivity
  • IR adapter connection for PC’s
  • Exposure Rate or Easy-Mode 1-9 Available
  • Network-Ready data feeds
  • Rugged and watertight
  • Stores event data in internal non-volatile memory
  • User-Friendly Configuration Software included
  • Highly sensitive detector coupled with highly accurate detector

Applications

  • Hospitals
  • Nuclear Power Plants
  • Radiation Safety Officers
  • Industrial Monitoring
  • Government Research Labs
  • U.S. Customs
  • Border Patrol
  • Security
  • Military
  • HAZMAT
  • Counter-Terrorism
  • Fire Departments
  • Medical Response
  • Police

SPECIFICATION

Detectors CsI(T1) scintillator Geiger-Muller tube
Sensitivity (for Cs-137) 1cps/(µR/h) (100 cps/(µSv/h))
Sensitivity (for Am-241) 0.7 cps/(µR/h) (70 cps/(µSv/h))
Energy Range (Measurement mode) 60 keV – 1.33 MeV Meets the ANSI 42.33 – 2003 (5.3.9);
Energy Range (Search mode) ANSI 42.33 – 2005 (6.3.1) requirements 60 keV – 3.0 MeV
DER Measurement Range 10µR/h – 10 R/h
DER Indication Range 1µR/h – 999 R/h
Maximum permissible intrinsic relative error of DER measurement ±(20+K/H) %, where H – DER value, mR/h; k – coefficient 0.5 mR/h
DE Measurement Range 10µR – 999R
DE Indication Range 0 µR – 999R
Maximum Permissible intrinsic relative error of DER measurement in measurement range ±20%
Response Time (time to alarm) at Dose Rate Increase by 50 µR/h for 0.5 s produced by 137Cs, 2 s