SKU:

Model 205 Dual Beam Ozone Monitor

Dual-beam UV absorption at 254 nm with two detection cells to improve precision, baseline stability, and response time. Lightweight with low power consumption and a quiet, long-life internal air pump. For research and monitoring applications where high precision and fast responses required.
  • 0-250 ppm measurement range with 1.0 ppb precision
  • Dual beam for heightened precision and fast measurements
  • 2-second measurement frequency (fastest available on the market)
  • Approved by the EPA as a FEM: EQOA-0410-190

Dual-beam UV absorption at 254 nm with two detection cells to improve precision, baseline stability, and response time. Lightweight with low power consumption and a quiet, long-life internal air pump. For research and monitoring applications where high precision and fast responses required.

  • 0-250 ppm measurement range with 1.0 ppb precision
  • Dual beam for heightened precision and fast measurements
  • 2-second measurement frequency (fastest available on the market)
  • Approved by the EPA as a FEM: EQOA-0410-190

Loading...

Description

Measurement Principle UV Absorption at 254 nm; Dual Beam
Federal Equivalent Method (FEM) Yes, 0-500 ppb for 10-40°C: EQOA-0410-190
Linear Dynamic Range 0 to 250 ppm
Resolution 0.1 ppb
Precision (1σ rms noise) Greater of 1.0 ppb or 2% of reading for 10-s average
Accuracy Greater of 1.0 ppb or 2% of reading
Limit of Detection (2σ) 2.0 ppb for 10-s average
NIST-Traceable Calibration Yes
Measurement Interval 2 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr)
Flow Rate (nominal) ~1.8 Liter/min
Flow Rate Requirement >1.2 L/min
Baseline Drift < 1 ppb/day
< 3 ppb/year
Sensitivity Drift < 1%/day
< 3%/year
Measurement Time, Frequency 2 s, 0.5 Hz
Response Time, 100% of Step Change 4 s, 2 points
Measurement and Averaging Times 2 s, 10 s, 1 min, 5 min, 1 hr
Ozone Units ppb, pphm, ppm, µg m-3, mg m-3
Pressure Units mbar, torr
Temperature Units °C, K
T and P Corrected Yes
Operating Temperature Range 0 to 50°C standard; optional -20 to 50°C with low temperature modifications (pump and lamp heater cold-weather package)
Operating Altitude Range ~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor
Power Requirement;
Supplied by battery or 110/220 VAC Power Pack
12 V dc or 120/240 V ac, nominally 650 mA at 12 V, ~8 watt (~7 watt with cell heater unplugged)
Size 3.7H x 8.5W x 11.8L inches (9.5 x 21.5 x 30 cm)
Weight 5.8 lb (2.6 kg); 3.1 lb (1.4 kg) without instrument case
Internal Data Logger Capacity 16,383 lines (2-s fast measurement mode = 9.1 hr; 10 s avg. = 1.9 days;
1 min avg = 11 days; 5 min avg = 1.9 mo; 1 hr avg = 1.9 yr
SD Card Logger Capacity > 2 GB (> 5-year capacity for 10-s averaging mode)
Analog Inputs for Internal Logging of Other Instruments 3 Analog Inputs, 0-2.5 V; For example, could log external T, P, and RH
Data Outputs RS232, 0-2.5 V Analog, LCD Display (Optional 4-20 mA Current; request quote)
Data Transfer Baud Rates 2400, 4800, 19200
Output Ranges User-Defined Scaling Factor in Menu
DewLine™ Yes
Quiet, Long-Life Internal Air Pump Yes
Flow Meter Yes
Options Battery; External Particle Filter; Serial-to-USB Adapter; GPS (for 10-s data mode and above); Bluetooth; 4-20 mA Current Output; Cold-Weather Package, -20 to 50° C (pump, lamp heater); High-Altitude Upgrade 0-25 km (pressure sensor); Extra-Long-Life, Low-Temperature Internal Air Pump; Low-Power Option; Rack-Mount Case Configuration

Product Details

  • Makes use of two detection cells to improve precision, baseline stability, and response time
  • UV light intensity measurements Io (ozone-scrubbed air) and I (unscrubbed air) are made simultaneously
  • Fastest UV-based ozone monitor on the market, while still retaining the small size, weight, and power requirements of our popular Model 202 Ozone Monitor
  • Desirable for aircraft and balloon measurements where high spatial resolution is needed
  • For 10-s averaging, a precision of 1.0 ppb is achieved.  Alternatively, one can choose to average more points internally to obtain even better precision
  • Flash card memory and a long-life, quiet internal air sampling pump are now standard on the instrument
  • Rackmount configuration available as an optional upgrade

Schematic Diagram