<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ozone Monitor &#8211; Lee Hung Scientific Pte Ltd</title>
	<atom:link href="https://www.leehung.com/product-category/environmental-monitoring-equipment/ozone-monitor/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.leehung.com</link>
	<description>4 Essential Science Laboratory Instruments For Your Chemistry La</description>
	<lastBuildDate>Fri, 28 Mar 2025 09:11:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.leehung.com/wp-content/uploads/2021/03/apple-touch-icon-100x100.png</url>
	<title>Ozone Monitor &#8211; Lee Hung Scientific Pte Ltd</title>
	<link>https://www.leehung.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Model 205 Dual Beam Ozone Monitor</title>
		<link>https://www.leehung.com/product/ozone-monitor-model-205/</link>
		
		<dc:creator><![CDATA[YuCheng]]></dc:creator>
		<pubDate>Wed, 29 Mar 2023 08:00:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.leehung.com/product/ozone-monitor-model-205/</guid>

					<description><![CDATA[<p>Dual-beam UV absorption at 254 nm with two detection cells to improve precision, baseline stability, and response time. Lightweight with low power consumption and a quiet, long-life internal air pump. For research and monitoring applications where high precision and fast responses required.</p>
<ul>
<li>0-250 ppm measurement range with 1.0 ppb precision</li>
<li>Dual beam for heightened precision and fast measurements</li>
<li>2-second measurement frequency (fastest available on the market)</li>
<li>Approved by the EPA as a FEM: <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA-0410-190</a></li>
</ul>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-205/">Model 205 Dual Beam Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table width="100%">
<tbody>
<tr>
<td width="32%" height="27"><strong>Measurement Principle</strong></td>
<td width="68%" height="27">UV Absorption at 254 nm; Dual Beam</td>
</tr>
<tr>
<td width="32%" height="27"><strong>Federal Equivalent Method (FEM)</strong></td>
<td width="68%" height="27">Yes, 0-500 ppb for 10-40°C: <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA-0410-190</a></td>
</tr>
<tr>
<td width="32%" height="26"><strong>Linear Dynamic Range</strong></td>
<td width="68%" height="26">0 to 250 ppm</td>
</tr>
<tr>
<td height="24"><strong>Resolution</strong></td>
<td height="24">0.1 ppb</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Precision (1σ rms noise)</strong></td>
<td width="68%" height="24">Greater of 1.0 ppb or 2% of reading for 10-s average</td>
</tr>
<tr>
<td height="25"><strong>Accuracy</strong></td>
<td height="25">Greater of 1.0 ppb or 2% of reading</td>
</tr>
<tr>
<td height="25"><strong>Limit of Detection (2σ)</strong></td>
<td height="25">2.0 ppb for 10-s average</td>
</tr>
<tr>
<td height="25"><strong>NIST-Traceable Calibration</strong></td>
<td height="25">Yes</td>
</tr>
<tr>
<td width="32%" height="25"><strong>Measurement Interval</strong></td>
<td width="68%" height="25">2 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Flow Rate (nominal)</strong></td>
<td width="68%" height="24">~1.8 Liter/min</td>
</tr>
<tr>
<td height="24"><strong>Flow Rate Requirement</strong></td>
<td height="24">&gt;1.2 L/min</td>
</tr>
<tr>
<td height="24"><strong>Baseline Drift</strong></td>
<td height="24">&lt; 1 ppb/day<br />
&lt; 3 ppb/year</td>
</tr>
<tr>
<td height="24"><strong>Sensitivity Drift</strong></td>
<td height="24">&lt; 1%/day<br />
&lt; 3%/year</td>
</tr>
<tr>
<td height="24"><strong>Measurement Time, Frequency</strong></td>
<td height="24">2 s, 0.5 Hz</td>
</tr>
<tr>
<td height="24"><strong>Response Time, 100% of Step Change</strong></td>
<td height="24">4 s, 2 points</td>
</tr>
<tr>
<td height="24"><strong>Measurement and Averaging Times</strong></td>
<td height="24">2 s, 10 s, 1 min, 5 min, 1 hr</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Ozone Units</strong></td>
<td width="68%" height="24">ppb, pphm, ppm, µg m<sup>-3</sup>, mg m<sup>-3</sup></td>
</tr>
<tr>
<td height="23"><strong>Pressure Units</strong></td>
<td height="23">mbar, torr</td>
</tr>
<tr>
<td height="23"><strong>Temperature Units</strong></td>
<td height="23">°C, K</td>
</tr>
<tr>
<td height="23"><strong>T and P Corrected</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Operating Temperature Range</strong></td>
<td height="23">0 to 50°C standard; optional -20 to 50°C with low temperature modifications (pump and lamp heater cold-weather package)</td>
</tr>
<tr>
<td height="23"><strong>Operating Altitude Range</strong></td>
<td height="23">~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Power Requirement;<br />
Supplied by battery or 110/220 VAC Power Pack</strong></td>
<td width="68%" height="23">12 V dc or 120/240 V ac, nominally 650 mA at 12 V, ~8 watt (~7 watt with cell heater unplugged)</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Size</strong></td>
<td width="68%" height="23">3.7H x 8.5W x 11.8L inches (9.5 x 21.5 x 30 cm)</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Weight</strong></td>
<td width="68%" height="23">5.8 lb (2.6 kg); 3.1 lb (1.4 kg) without instrument case</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Internal Data Logger Capacity</strong></td>
<td width="68%" height="24">16,383 lines (2-s fast measurement mode = 9.1 hr; 10 s avg. = 1.9 days;<br />
1 min avg = 11 days; 5 min avg = 1.9 mo; 1 hr avg = 1.9 yr</td>
</tr>
<tr>
<td width="32%" height="23"><strong>SD Card Logger Capacity</strong></td>
<td width="68%" height="23">&gt; 2 GB (&gt; 5-year capacity for 10-s averaging mode)</td>
</tr>
<tr>
<td height="23"><strong>Analog Inputs for Internal Logging of Other Instruments</strong></td>
<td height="23">3 Analog Inputs, 0-2.5 V; For example, could log external T, P, and RH</td>
</tr>
<tr>
<td height="23"><strong>Data Outputs</strong></td>
<td height="23">RS232, 0-2.5 V Analog, LCD Display (Optional 4-20 mA Current; request quote)</td>
</tr>
<tr>
<td height="23"><strong>Data Transfer Baud Rates</strong></td>
<td height="23">2400, 4800, 19200</td>
</tr>
<tr>
<td height="23"><strong>Output Ranges</strong></td>
<td height="23">User-Defined Scaling Factor in Menu</td>
</tr>
<tr>
<td height="23"><strong>DewLine™</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Quiet, Long-Life Internal Air Pump</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Flow Meter</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Options</strong></td>
<td height="23">Battery; External Particle Filter; Serial-to-USB Adapter; GPS (for 10-s data mode and above); Bluetooth; 4-20 mA Current Output; Cold-Weather Package, -20 to 50° C (pump, lamp heater); High-Altitude Upgrade 0-25 km (pressure sensor); Extra-Long-Life, Low-Temperature Internal Air Pump; Low-Power Option; Rack-Mount Case Configuration</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-205/">Model 205 Dual Beam Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 202 Ozone Monitor</title>
		<link>https://www.leehung.com/product/ozone-monitor-model-202/</link>
		
		<dc:creator><![CDATA[YuCheng]]></dc:creator>
		<pubDate>Wed, 29 Mar 2023 08:00:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.leehung.com/product/ozone-monitor-model-202/</guid>

					<description><![CDATA[<p>Features real-time ozone measurements produced every 10 seconds. Robust and versatile ozone monitor used for a variety of ambient ozone monitoring applications.</p>
<ul>
<li>0-250 ppm with 1.5 ppb precision</li>
<li>EPA-certified FEM (<a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf">EQOA-0410-190</a>)</li>
<li>Highly portable, low power, benchtop ozone monitor</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-202/">Model 202 Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table width="100%">
<tbody>
<tr>
<td width="32%" height="27"><strong>Measurement Principle</strong></td>
<td width="68%" height="27">UV Absorption at 254 nm, single beam</td>
</tr>
<tr>
<td width="32%" height="27"><strong>Federal Equivalent Method (FEM)</strong></td>
<td width="68%" height="27">Yes, 0-500 ppb for 10-40°C: <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA-0410-190</a></td>
</tr>
<tr>
<td width="32%" height="26"><strong>Linear Dynamic Range</strong></td>
<td width="68%" height="26">0 to 250 ppm</td>
</tr>
<tr>
<td height="24"><strong>Resolution</strong></td>
<td height="24">0.1 ppb</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Precision (1σ; rms noise)</strong></td>
<td width="68%" height="24">Greater of 1.5 ppb or 2% of reading</td>
</tr>
<tr>
<td height="25"><strong>Accuracy</strong></td>
<td height="25">Greater of 1.5 ppb or 2% of reading</td>
</tr>
<tr>
<td height="25"><strong>Limit of Detection (2σ)</strong></td>
<td height="25">3.0 ppb (in 10-s measurement mode)</td>
</tr>
<tr>
<td height="25"><strong>NIST-Traceable Calibration</strong></td>
<td height="25">Yes</td>
</tr>
<tr>
<td width="32%" height="25"><strong>Measurement Interval</strong></td>
<td width="68%" height="25">10 s (Data averaging options: 1 min, 5 min, 1 hr)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Flow Rate (nominal)</strong></td>
<td width="68%" height="24">~1 Liter/min</td>
</tr>
<tr>
<td height="24"><strong>Flow Rate Requirement</strong></td>
<td height="24">&gt;0.6 L/min</td>
</tr>
<tr>
<td height="24"><strong>Baseline Drift</strong></td>
<td height="24">&lt; 2 ppb/day<br />
&lt; 5 ppb/year</td>
</tr>
<tr>
<td height="24"><strong>Sensitivity Drift</strong></td>
<td height="24">&lt; 1%/day<br />
&lt; 3%/year</td>
</tr>
<tr>
<td height="24"><strong>Measurement Time, Frequency</strong></td>
<td height="24">10 s, 0.1 Hz</td>
</tr>
<tr>
<td height="24"><strong>Response Time, 100% of Step Change</strong></td>
<td height="24">20 s, 2 points</td>
</tr>
<tr>
<td height="24"><strong>Averaging Times</strong></td>
<td height="24">1 min, 5 min, 1 hr</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Internal Data Logger Capacity</strong></td>
<td width="68%" height="24">16,383 lines (10-s meas. = 1.9 days; 1-min avg = 11 days; 5-min avg = 1.9 mo;<br />
1-hr avg = 1.9 yr)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>SD Card Logger Capacity</strong></td>
<td width="68%" height="24">Minimum 2 GB (&gt; 5-year capacity for 10-s measurement mode)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Ozone Units</strong></td>
<td width="68%" height="24">ppb, ppm, pphm, µg m<sup>-3</sup>, mg m<sup>-3</sup></td>
</tr>
<tr>
<td height="23"><strong>Pressure Units</strong></td>
<td height="23">mbar, torr</td>
</tr>
<tr>
<td height="23"><strong>Temperature Units</strong></td>
<td height="23">°C, K</td>
</tr>
<tr>
<td height="23"><strong>T and P Corrected</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Operating Temperature Range</strong></td>
<td height="23">0 to 50 °C standard; optional -20 to 50 °C with low temperature modifications (pump and lamp heater cold-weather package)</td>
</tr>
<tr>
<td height="23"><strong>Operating Altitude Range</strong></td>
<td height="23">~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Power Requirement;<br />
Supplied by battery or 110/220 VAC Power Pack</strong></td>
<td width="68%" height="23">11-14 V DC or 120/240 V AC, 600 mA, 7.2 watt (6.2 watt with cell heater unplugged)</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Size</strong></td>
<td width="68%" height="23">3.7H x 8.5W x 11.8L inches (9.5 x 21.5 x 30 cm)</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Weight</strong></td>
<td width="68%" height="23">5.5 lb (2.5 kg); 2.8 lb (1.3 kg) without instrument case</td>
</tr>
<tr>
<td height="23"><strong>Analog Inputs for Internal Logging of Other Instruments</strong></td>
<td height="23">3 Analog Inputs, 0-2.5 V; For example could log external T, P and RH</td>
</tr>
<tr>
<td height="23"><strong>Data Outputs</strong></td>
<td height="23">RS232, 0-2.5 V Analog, LCD Display: (Optional 4-20 mA Analog Current output; request quote)</td>
</tr>
<tr>
<td height="23"><strong>Data Transfer Baud Rates</strong></td>
<td height="23">2400, 4800, 19200</td>
</tr>
<tr>
<td height="23"><strong>Output Ranges</strong></td>
<td height="23">User-Defined Scaling Factor in Menu</td>
</tr>
<tr>
<td height="23"><strong>DewLine™</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Quiet Long-Life Internal Air Pump</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Flow Meter</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Options</strong></td>
<td height="23">Battery; External Particle Filter; Serial-to-USB Converter; GPS (for 10-s data mode and above); Bluetooth; 4-20 mA Current Output; Cold-Weather Package, -20 to 50°C (pump, lamp heater); High-Altitude Upgrade (25 km); Extra-Long-Life Internal Air Pump; Lower-Power Option; Rack-Mount Case Configuration</td>
</tr>
<tr>
<td height="23"><strong>Upgradable to Model 205 Dual Beam</strong></td>
<td height="23">Yes</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-202/">Model 202 Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 106-L Ozone Monitor</title>
		<link>https://www.leehung.com/product/ozone-monitor-model-106-lmh/</link>
		
		<dc:creator><![CDATA[YuCheng]]></dc:creator>
		<pubDate>Wed, 29 Mar 2023 08:00:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.leehung.com/product/ozone-monitor-model-106-lmh/</guid>

					<description><![CDATA[<p><strong>Measuring range of 0-20 ppm with 1.5 ppb precision</strong></p>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-106-lmh/">Model 106-L Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Versatile ambient Federal Equivalent Method (FEM) ozone monitor designed for both outdoor and industrial compliance monitoring applications. Ideal for industrial applications including: workplace exposure monitoring, fruit/vegetable cold storage, ozone disinfection, and many others.</p>
<p>The Model 106-L Ozone Monitor is designed for measurements of ozone concentrations ranging from low ppb levels up to 20 ppm (20,000 ppb). This highly accurate ozone monitor (1.5 ppb) has a low limit of detection (3.0 ppb for 10 second measurements) and is certified by the EPA as a FEM for monitoring for compliance with the US Clean Air Act:  <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA-0914-218</a>.</p>
<h2 class="wp-block-heading"><strong>About the 106 Series:</strong></h2>
<ul>
<li>Designed for industrial ozone applications to cover four different ozone concentration ranges by varying the optical path length.</li>
<li>Highly robust and easy to service; all components are mounted directly to the printed circuit board with few wire connection</li>
<li>Available in the three following configurations: Standard Enclosure, Industrial Enclosure, or with no enclosure (OEM version)</li>
<li>Industrial/NEMA Enclosure is available with single channel, three channel, or six channel sampling manifolds (106-H only available as single channel)</li>
</ul>
<h2 class="wp-block-heading"><strong>Features</strong></h2>
<ul>
<li>UV absorption-based measurements, single beam</li>
<li>Low power consumption</li>
<li>Internal data logger with real-time clock</li>
<li>​2-s measurement interval</li>
<li>On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m, 5 m, 1 hr, and user-defined adaptive filter</li>
<li>USB and RS-232 output of time/date, O<sub>3</sub> concentration, internal temperature and pressure</li>
<li>Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user-selected units and scaling factors</li>
<li>Two 2-level relays for control purposes (e.g., control of ozone source or turn warning light on and off); Four relays on Industrial enclosure models and in the 3-channel and 6-channel optional configurations</li>
<li>Long-life pump (15,000 hr)</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/ozone-monitor-model-106-lmh/">Model 106-L Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 211 Scrubberless Ozone Monitor</title>
		<link>https://www.leehung.com/product/model-211-scrubberless-ozone-monitor/</link>
		
		<dc:creator><![CDATA[YuCheng]]></dc:creator>
		<pubDate>Wed, 29 Mar 2023 08:00:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.leehung.com/product/ozone-monitor-model-211/</guid>

					<description><![CDATA[<p>Dual beam ozone monitor FEM with a 30-cm pathlength. Patented gas-phase titration scrubber technology used in place of a solid-phase scrubber to minimize interferences. Ideal for ambient ozone monitoring in regions that are in non-attainment for ozone.</p>
<ul>
<li>Dual beam, long path (30 cm) optical bench with high precision (&#60; 0.5 ppb)</li>
<li>EPA Federal Equivalent Method (FEM) for compliance monitoring (<a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA–0514–215</a>)</li>
<li>“Scrubberless” for interference-free measurement of ambient ozone</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/model-211-scrubberless-ozone-monitor/">Model 211 Scrubberless Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table width="100%">
<tbody>
<tr>
<td width="34%"><strong>Measurement Principle</strong></td>
<td width="66%" height="26">UV Absorbance at 254 nm; Dual Beam</td>
</tr>
<tr>
<td width="34%"><strong>Federal Equivalent Method (FEM)</strong></td>
<td width="66%">Yes, 0-500 ppb for 20-30°C: <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA–0514–215</a></td>
</tr>
<tr>
<td width="34%"><strong>Ozone Scrubber Technology</strong></td>
<td width="66%" height="26">Gas-phase scrubber using NO, provided directly or by photolysis of N<sub>2</sub>O (supplied by either compressed gas cylinder or portable liquid N<sub>2</sub>O cartridge)</td>
</tr>
<tr>
<td width="34%"><strong>Linear Dynamic Range</strong></td>
<td width="66%">0-2,000 ppb (0-2 ppm)</td>
</tr>
<tr>
<td><strong>Resolution</strong></td>
<td height="24">0.1 ppb</td>
</tr>
<tr>
<td width="34%"><strong>Precision (1σ rms noise)</strong></td>
<td width="66%">Greater of 0.5 ppb or 1% of reading for 10-s average</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td>Greater of 1.0 ppb or 2% of reading</td>
</tr>
<tr>
<td><strong>Limit of Detection (2σ)</strong></td>
<td>1.0 ppb for 10-s average</td>
</tr>
<tr>
<td><strong>NIST-Traceable Calibration</strong></td>
<td>Yes</td>
</tr>
<tr>
<td width="34%"><strong>Flow Rate (nominal)</strong></td>
<td width="66%">~2 Liter/min</td>
</tr>
<tr>
<td><strong>Flow Rate Requirement</strong></td>
<td>&gt;1.2 L/min</td>
</tr>
<tr>
<td height="42"><strong>Baseline Drift</strong></td>
<td>&lt; 1 ppb/day<br />
&lt; 3 ppb/year</td>
</tr>
<tr>
<td height="42"><strong>Sensitivity Drift</strong></td>
<td>&lt; 0.5%/day<br />
&lt; 3%/year</td>
</tr>
<tr>
<td><strong>Response Time, 100% of Step Change</strong></td>
<td height="24">20 s for 10-s averaging; 4 s for 2-s measurement</td>
</tr>
<tr>
<td><strong>Measurement and Averaging Times</strong></td>
<td>2 s, 10 s, 1 min, 5 min, 1 hr</td>
</tr>
<tr>
<td width="34%"><strong>Internal Data Logger Capacity</strong></td>
<td width="66%">16,383 lines (10-s avg. = 1.9 days; 1-min avg = 11 days; 5-min avg = 1.9 mo; 1-hr avg = 1.9 yr)</td>
</tr>
<tr>
<td><strong>SD Card Logger Capacity</strong></td>
<td>Minimum 2 GB (&gt; 5-year capacity for 10-s measurement mode)</td>
</tr>
<tr>
<td width="34%"><strong>Ozone Units</strong></td>
<td width="66%">ppb, ppm, pphm, µg m<sup>-3</sup>, mg m<sup>-3</sup></td>
</tr>
<tr>
<td><strong>Pressure Units</strong></td>
<td>mbar, torr</td>
</tr>
<tr>
<td><strong>Temperature Units</strong></td>
<td>°C, K</td>
</tr>
<tr>
<td><strong>T and P Corrected</strong></td>
<td>Yes</td>
</tr>
<tr>
<td><strong>Operating Temperature Range</strong></td>
<td>10 to 50 °C</td>
</tr>
<tr>
<td><strong>Operating Altitude Range</strong></td>
<td>~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor</td>
</tr>
<tr>
<td width="34%"><strong>Power Requirement;<br />
Supplied by Battery or 110/220 VAC Power Pack</strong></td>
<td width="66%" height="23">11-14 V dc or 120/240 V ac, 1 A at 12 V, 12 watt</td>
</tr>
<tr>
<td width="34%"><strong>Size</strong></td>
<td width="66%">Rackmount: 17″ w x 14.5″ d x 5.5″ h (43 x 37 x 14 cm)</td>
</tr>
<tr>
<td width="34%"><strong>Weight</strong></td>
<td width="66%">14.7 lb (6.7 kg)</td>
</tr>
<tr>
<td><strong>Data Outputs</strong></td>
<td>RS232, SD data card, LCD, 0-2.5 V Analog, optional 4-20 mA Analog</td>
</tr>
<tr>
<td><strong>Data Transfer Baud Rates</strong></td>
<td>2400, 4800, 19200</td>
</tr>
<tr>
<td><strong>Output Ranges</strong></td>
<td>User-Defined Scaling Factor in Menu</td>
</tr>
<tr>
<td><strong>DewLine™</strong></td>
<td>Yes</td>
</tr>
<tr>
<td><strong>Long-Life Pump</strong></td>
<td>Yes, 20,000 hr</td>
</tr>
<tr>
<td><strong>Flow Meter</strong></td>
<td>Yes</td>
</tr>
<tr>
<td><strong>Options</strong></td>
<td>Battery; External Particle Filter; Bluetooth; External Serial-to-USB Adapter; 4-20 mA Current Output; Lamp Heater; High-Altitude Upgrade, ~0-25 km (pressure sensor)</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/model-211-scrubberless-ozone-monitor/">Model 211 Scrubberless Ozone Monitor</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Personal Ozone Monitor (POM)</title>
		<link>https://www.leehung.com/product/personal-ozone-monitor/</link>
		
		<dc:creator><![CDATA[YuCheng]]></dc:creator>
		<pubDate>Wed, 29 Mar 2023 08:00:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.leehung.com/product/personal-ozone-monitor/</guid>

					<description><![CDATA[<p>Handheld EPA-certified Federal Equivalent Method (FEM) ozone monitor that utilizes the measurement technique of UV absorption.</p>
<ul>
<li>0-10 ppm measurement range with 1.5 ppb precision</li>
<li>Handheld with battery and GPS</li>
<li>EPA designated as a Federal Equivalent Method (FEM) for ozone: <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA–0815–227</a>.</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/personal-ozone-monitor/">Personal Ozone Monitor (POM)</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table width="100%">
<tbody>
<tr>
<td width="32%" height="27"><strong>Measurement Principle</strong></td>
<td width="68%" height="27">UV Absorption at 254 nm</td>
</tr>
<tr>
<td width="32%" height="26"><strong>Federal Equivalent Method (FEM)</strong></td>
<td width="68%" height="26">Yes, <a href="https://2btech.io/wp-content/uploads/docs/FRM_FEM_EPAlist.pdf" target="_blank" rel="noopener">EQOA–0815–227</a></td>
</tr>
<tr>
<td width="32%" height="26"><strong>Linear Dynamic Range</strong></td>
<td width="68%" height="26">0 ppb to 10 ppm</td>
</tr>
<tr>
<td height="24"><strong>Resolution</strong></td>
<td height="24">0.1 ppb</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Precision (1σ rms noise)</strong></td>
<td width="68%" height="24">Greater of 1.5 ppb or 2% of reading</td>
</tr>
<tr>
<td height="25"><strong>Accuracy</strong></td>
<td height="25">Greater of 1.5 ppb or 2% of reading</td>
</tr>
<tr>
<td height="25"><strong>Limit of Detection (2σ)</strong></td>
<td height="25">3.0 ppb (10-s measurement mode, with default adaptive filter settings)</td>
</tr>
<tr>
<td height="25"><strong>NIST-Traceable Calibration</strong></td>
<td height="25">Yes</td>
</tr>
<tr>
<td width="32%" height="25"><strong>Measurement Intervals</strong></td>
<td width="68%" height="25">Measurement mode: 10 s (Fast mode: 2 s)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Flow Rate (nominal)</strong></td>
<td width="68%" height="24">~0.8 Liter/min</td>
</tr>
<tr>
<td height="24"><strong>Flow Rate Requirement</strong></td>
<td height="24">&gt;0.5 L/min</td>
</tr>
<tr>
<td height="24"><strong>Baseline Drift</strong></td>
<td height="24">&lt; 2 ppb/day<br />
&lt; 5 ppb/year</td>
</tr>
<tr>
<td height="24"><strong>Sensitivity Drift</strong></td>
<td height="24">&lt; 1%/day<br />
&lt; 3%/year</td>
</tr>
<tr>
<td height="24"><strong>Measurement Time, Frequency</strong></td>
<td height="24">10 s, 0.1 Hz (Fast mode: 2 s, 0.5 Hz)</td>
</tr>
<tr>
<td height="24"><strong>Response Time, 100% of Step Change</strong></td>
<td height="24">For 10-s output: 20 s, 2 points (For 2-s output: 4 s, 2 points)</td>
</tr>
<tr>
<td height="24"><strong>Averaging Times</strong></td>
<td height="24">1 min, 5 min, 1 hr</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Data Storage</strong></td>
<td width="68%" height="24">8,192 lines (2-s fast mode ~4.6 hr; 10-s meas. mode ~1 day; 1-min avg ~6 days; 5-min avg ~1 mo; 1-hr avg ~1 yr)</td>
</tr>
<tr>
<td width="32%" height="24"><strong>Ozone Units</strong></td>
<td width="68%" height="24">ppb</td>
</tr>
<tr>
<td height="23"><strong>Pressure Units</strong></td>
<td height="23">torr</td>
</tr>
<tr>
<td height="23"><strong>Temperature Units</strong></td>
<td height="23">K</td>
</tr>
<tr>
<td height="23"><strong>T and P Corrected</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Operating Temperature Range</strong></td>
<td height="23">0 to 50 °C</td>
</tr>
<tr>
<td height="23"><strong>Operating Altitude/Pressure Ranges</strong></td>
<td height="23">~0-13.5 km (150-1,013 mbar) [modifications for higher altitudes available as an option]</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Power Requirement;<br />
Supplied by battery or 110/220 VAC Power Pack</strong></td>
<td width="68%" height="23">7-12 V dc, nominally 250 mA at 12 V, 3.0 watt</td>
</tr>
<tr>
<td width="32%" height="23"><strong>External Battery</strong></td>
<td width="68%" height="23">7.4 Volt, 1.6 amp hour, Lithium Ion Battery, 5-8 hr</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Size</strong></td>
<td width="68%" height="23">without GPS and battery: 4.0 x 3.0 x 1.5 inches (10.2 x 7.6 x 3.8 cm)<br />
add GPS: 5.0 x 3.0 x 1.5 in (12.7 x 7.6 x 3.8 cm)</td>
</tr>
<tr>
<td width="32%" height="23"><strong>Weight</strong></td>
<td width="68%" height="23">without battery: 0.8 lb (0.36 kg)<br />
with battery: 1.0 lb (0.45 kg)</td>
</tr>
<tr>
<td height="23"><strong>Data Transfer Baud Rate</strong></td>
<td height="23">19200</td>
</tr>
<tr>
<td height="23"><strong>DewLine™</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>GPS</strong></td>
<td height="23">Yes</td>
</tr>
<tr>
<td height="23"><strong>Options</strong></td>
<td height="23">Analog output; wall-mount bracket; modifications for higher altitude operation; Pelican-brand carrying case</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.leehung.com/product/personal-ozone-monitor/">Personal Ozone Monitor (POM)</a> appeared first on <a rel="nofollow" href="https://www.leehung.com">Lee Hung Scientific Pte Ltd</a>.</p>